Belden 1213 Cable
The Belden 1213 Cat 5e network cable is cUL/CSA certified as FT6 and is suitable for indoor applications. We offer the Belden 1213 cable in blue or white Flamarrest® LS PVC outerjacket material to assist with color coding at installation. The Belden 1213 cable jacket is sequentially marked at 2 foot/1 meter intervals.
For white outerjacket, see Belden Cat 5e 1213 white.
Belden 1213 Cable Cat 5e FT6 Plenum Cable 1000 ft., Blue
CAT5e+ (350MHz), 4-Pair, U/UTP-unshielded, Plenum-CMP, Premise Horizontal cable, 24 AWG solid bare copper conductors, dual FRPO/FEP insulation, ripcord, Flamarrest® jacket
Environmental Space: |
Plenum |
Suitable Applications: |
Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 |
Physical Characteristics (Overall)
Conductor
AWG |
Stranding |
Material |
No. of Pairs |
24 |
Solid |
BC – Bare Copper |
4 |
Insulation
Material |
FRPO/FEP – Flame Retardant Polyolefin/Fluorinated Ethylene Propylene |
Color Chart
Number |
Color |
1 |
White/Blue Stripe & Blue |
2 |
White/Orange Stripe & Orange |
3 |
White/Green Stripe & Green |
4 |
White/Brown Stripe & Brown |
Outer Jacket Material
Material |
Material Trade Name |
Nominal Diameter |
Ripcord |
LS PVC – Low Smoke Polyvinyl Chloride |
Flamarrest® |
0.207 in |
Yes |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR |
Max. DCR Unbalance |
89 Ohm/km |
3 % |
Capacitance
Max. Capacitance Unbalance |
Nom.Mutual Capacitance |
330 pF/100m |
15 pF/ft |
Delay
Frequency [MHz] |
Max. Delay |
Max. Delay Skew |
Nominal Velocity of Propagation (VP) [%] |
100 MHz |
537.6 ns/100m |
25 ns/100m |
72 % |
High Freq
Voltage
UL Voltage Rating |
300 V RMS |
Temperature Range
Installation Temp Range: |
0°C To +50°C |
Storage Temp Range: |
-20°C To +75°C |
Operating Temp Range: |
-20°C To +75°C |
Mechanical Characteristics
Bulk Cable Weight: |
22 lbs/1000ft |
Max Recommended Pulling Tension: |
25 lbs |
Min Bend Radius During Installation: |
2.75 in |
Min Bend Radius/Minor Axis: |
2.25 in |
Standards
NEC/(UL) Specification: |
CMP |
CEC/C(UL) Specification: |
CMP |
ISO/IEC Compliance: |
11801 ed 2.2 (2011) Class D |
Data Category: |
Category 5e |
ANSI Compliance: |
S-90-661-2012 Category 5e, ANSI/NEMA WC-63.1 Category 5e |
Telecommunications Standards: |
ANSI/TIA-568-C.2 Category 5e |
IEEE Specification: |
IEEE 802.3bt Type 1, Type 2, Type 3 |
Third Party Performance Verification: |
Category 5e |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
EU Directive 2003/96/EC (BFR): |
Yes |
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU: |
Yes |
EU Directive Compliance: |
Yes |
EU REACH SVHC Compliance (yyyy-mm-dd): |
2017-07-10 |
EU RoHS Compliance Date (yyyy-mm-dd): |
2011-12-09 |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Hazardous Locations: |
No |
Suitability – Indoor: |
Yes |
Suitability – Non-Halogenated: |
No |
Suitability – Oil Resistance: |
No |
Suitability – Outdoor: |
No |
Suitability – Sunlight Resistance: |
No |
Flammability, LS0H, Toxicity Testing
UL Flammability: |
NFPA 262 Plenum (UL 910) |
ISO/IEC Flammability: |
IEC 60332-1-2 |
UL voltage rating: |
300 V RMS |
Plenum/Non-Plenum
Part Number
Belden 1213 Variants
Footnote: |
C – CRATE REEL PUT-UP. |
Patent: |
https://www.belden.com/resources/patents |
Product Notes
Notes: |
Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. |
History
Update and Revision: |
Revision Number: 0.337 Revision Date: 08-22-2019 |
There are no reviews yet.